How the box communicates across phases
By Christian · 27 November 2026
Three-Phase Installations and Communication Between ZenseHome Devices
In a three-phase electrical installation, three phases are supplied to the building. All ZenseHome devices communicate over one of these three phases.
Communication Between the ZenseHome Box and Devices
The ZenseHome box has three built-in modems, one for each phase. Each modem communicates with the devices connected to its respective phase. The ZenseHome box also ensures that devices connected to different phases can communicate with each other.
For the ZenseHome box to communicate with a device, it must know which phase the device is connected to. This is determined by running a communication test. During the test, the system sends a signal on each phase and measures how many times the device responds. The results are converted into percentages that indicate the communication quality on each phase.
Selecting the Phase Used for Communication
In many installations, you may see communication percentages on more than one phase. This does not mean that the device is connected to multiple phases.
What can happen is that cables carrying Phase 1 and Phase 2 cross each other somewhere in the electrical installation. When this occurs, the signal can "jump" from one phase to another. In systems where this happens, the ZenseHome box automatically handles it and uses the phase that provides the best communication.
Changes in the installation can sometimes reduce communication quality on the phase currently being used. If this happens, the system will automatically attempt to reach the device through one of the other phases, provided those phases have previously demonstrated good communication.
In relation to the phases and the percentages shown in the app, all devices are physically installed on one or more phases that are distributed throughout your home.
Cross-Talk Between Phases
For example, device "X" may be connected to Phase 1 and would normally communicate through that phase. However, when signals are transmitted over the phases, cross-talk can occur if, for example, Phase 1 and Phase 2 cross each other or are routed very close together physically within the wiring. Cross-talk occurs when a signal physically jumps from one phase to another.
The system detects this as an opportunity to send a signal via Phase 2 to a device that is actually connected to Phase 1, because the signal can jump to the correct phase. If Phase 2 turns out to provide better communication with the device due to cross-talk, the system will automatically use Phase 2 as the preferred communication path, even though the device is installed on Phase 1. This is part of the intelligent design of our digital phase coupler.
As a result, communication percentages may appear on all three phases, since all three phases may cross each other or run close together somewhere in the wiring and therefore be able to reach the device.
Finally, changes may occur that reduce communication quality on the phase currently being used. In such cases, the system will automatically attempt to communicate through one of the other phases if previous tests have shown sufficient communication quality.
When Communication Is Considered Sufficient
The minimum required communication level is 50% on at least one phase.
For example:
- Phase 1: 0%
- Phase 2: 0%
- Phase 3: 50%
This means that even if there is no communication on two phases, communication is considered sufficient as long as one phase provides a communication level of 50% or higher. In that case, reliable communication can be maintained between the device and the ZenseHome box.