Installing current sensors for the ZenseHome Box
By Christian · 27 November 2026
The ZenseHome Box can measure the total electricity consumption of the house using current clamps on the incoming supply. The sensors can measure up to 100 A.
Markings: C1, C2, C3 and N.
- C1: Current clamp on L1 with current sensor.
- C2: Current clamp on L2 with current sensor.
- C3: Current clamp on L3 with current sensor.
- CN: Current clamp on N with current sensor.
Never connect 230 V to these terminals. They are for current clamps only.
Current sensor connections on C1, C2, C3 and CN
- C1, terminal 1: W (white)
- C1, terminal 2: R (red)
- C2, terminal 1: W (white)
- C2, terminal 2: R (red)
- C3, terminal 1: W (white)
- C3, terminal 2: R (red)
- CN, terminal 1: W (white)
- CN, terminal 2: R (red)
Install the current clamps downstream of the residual current device (HPFI/RCD), with the arrows pointing in the direction of current flow.