Installing current sensors for the ZenseHome Box

By Christian · 27 November 2026

The ZenseHome Box can measure the total electricity consumption of the house using current clamps on the incoming supply. The sensors can measure up to 100 A.

Markings: C1, C2, C3 and N.

  • C1: Current clamp on L1 with current sensor.
  • C2: Current clamp on L2 with current sensor.
  • C3: Current clamp on L3 with current sensor.
  • CN: Current clamp on N with current sensor.

Never connect 230 V to these terminals. They are for current clamps only.

Current sensor connections on C1, C2, C3 and CN

  • C1, terminal 1: W (white)
  • C1, terminal 2: R (red)
  • C2, terminal 1: W (white)
  • C2, terminal 2: R (red)
  • C3, terminal 1: W (white)
  • C3, terminal 2: R (red)
  • CN, terminal 1: W (white)
  • CN, terminal 2: R (red)

Install the current clamps downstream of the residual current device (HPFI/RCD), with the arrows pointing in the direction of current flow.